Skip to main content

What Gentle Pro Series Treatments Are For

Enhance your practice with the leading hair removal brand chosen by dermatologists.

Plus you don’t have to buy multiple lasers to treat multiple targets. Gentle Pro lasers go beyond hair removal to let you treat a myriad of indications as shown below. 

Indications

1064 nm or 755 nm

  • Stable, long-term, or permanent hair reduction (permanent hair reduction is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regimen)
  • Treatment of vascular lesions
  • Treatment of wrinkles
  • Treatment of benign pigmented lesions

1064 nm

  • Temporary increase of clear nail in patients with onychomycosis

Key Benefits of Gentle Pro Series

Designed to maximize patient satisfaction - and your practice’s success.

You’ll love what our lasers do for your business. 

    What our lasers do for your business.

    Versatility


    Our 755 nm and 1064 nm wavelength technology goes beyond hair removal to also let you treat wrinkles, benign pigmented lesions and vascular lesions. That flexibility can lead to new revenue and boost your ROI.

     

    High throughput


    As plastic surgeon Alan Gold, MD, says: “Quicker treatment times allow for greater business growth in my practice.”

     

    Proven performance


    Gentle Pro lasers have been the industry standard for two decades.

    Unmatched support after sale


    With over 21 years of expertise and more than 12,000 Gentle systems currently installed, you can count on Candela for:

    • Proven Results
    • Fast, reliable repairs performed by our own technicians
    • Marketing support to help you promote laser treatments
    • The most advanced technologies, now and tomorrow

    Before & After Photos

    Look at the difference you can make for your patients — in just weeks.

    GentlePro Series Product Features

    • Dual wavelengths for ultimate convenience
    • Multiple spot sizes from specialty sizes as small as 1.5 mm up to 24 mm
    • Patented DCD™ saves time, scales with fluence, and provides consistent protection
    • Plus Air Cooling option
    The demand for hair removal and Pigmented lesion treatments is growing
    Icon illustrating 52% of the population that has considered hair removal with an aesthetic device.

    52%

    of the population is considering hair removal with an aesthetic device2

    Icon illustrating up to 3 sessions for pigmented lesion treatments.

    3

    Average of 3 sessions for pigmented lesion treatments

    Icon illustrating hair removal as one of the top three non-surgical aesthetic treatments.

    Hair removal

    is one of the top 3 non-surgical aesthetic procedures3

    Bottom line: You have to experience these lasers for yourself.

    Let a Candela product expert show you all the unique features and capabilities that make Gentle Pro the gold standard in laser hair removal and more. 

     

    Marketing Education
    Millennials aren’t those kids with ironic t-shirts, selfie sticks, and self-esteem trophies anymore. They’ve grown up to accumulate $1 trillion dollars in spending power.1 They also have very strong feelings
    Marketing Education
    Male Aesthetic Market Study | Medical Insight
    Among the most popular procedures are: Body Shaping/Skin Tightening, Hair Removal, Fractional Skin Rejuvenation and Tattoo Removal. "Through 2019, total male market sales are expected to rise by 11.4% per

    Product Specifications

    Laser TypeNd:YAGAlexandrite
    Wavelength1064 nm755 nm
    RepetitionUp to 10 HzUp to 10 Hz
    Max Delivered Energy80 joules (J) 53 joules (J)
    Pulse Duration0.250-100 ms
    Spot Sizes6 mm, 8 mm, 10 mm, 12 mm, 15 mm, 18 mm
    λ2 Specialty Delivery System
    Option Spot Sizes
    Small - 1.5 mm, 3 mm, 5 mm, 3 x 10 mm
    Large - 20 mm, 22 mm, 24 mm
    Beam DeliveryLens-coupled optical fiber with handpiece
    Pulse ControlFinger switch, foot switch
    Dimensions107 cm H x 46 cm W x 69 cm D (42” x
    18” x 27”)
    Weight118 kg (260 lbs)
    Electrical200-240 VAC, 50/60 Hz, 30A, 4600 VA single phase
    Optional Dynamic Cooling Device Integrated controls, cryogen container and handpiece with distance gauge
    CryogenHFC 134a
    DCD Spray DurationUser adjustable range: 10-100 ms
    DCD Delay DurationUser adjustable range: 3, 5, 10-100 ms
    DCD Post Spray DurationUser adjustable range: 0-20 ms

    Optional Air Cooling Compatible (ACC) Handpiece Available

    1. Comparing 18- versus 12-mm spot size in hair removal using a Gentlelase 755-nm alexandrite laser. Nouri K, Chen H, Saghari S, Ricotti CA Jr. Dermatol Surg. 2004 Apr;30(4 Pt 1):494-7. Comparison of long-pulsed alexandrite and Nd:YAG lasers, individually and in combination, for leg hair reduction: an assessor-blinded, randomized trial with 18 months of follow-up. Davoudi SM, Behnia F, Gorouhi F, Keshavarz S, Nassiri Kashani M, Rashighi Firoozabadi M, Firooz A. Arch Dermatol. 2008 Oct;144(10):1323-7. doi: 10.1001/archderm.144.10.1323. Clinical comparison of four hair removal lasers and light sources. Amin SP, Goldberg DJ. J Cosmet Laser Ther. 2006 Jun;8(2):65-8. 
    2. American Society of Dermatological Surgery Survey, 2014. 
    3. ASAPS (The American Society for Aesthetic Plastic Surgery) 2016 U.S. Cosmetic Surgery National Data Bank Statistics.™ 

    PU03511EN, Rev. A